Universal Tile Vent

Product Code: KG985403 KG985430 KG985434 KG985436 KG985476

The universal solution is perfect for ventilating roof voids. It helps to reduce the build-up of mould growth and structural damage in the roof space, caused by damp, poorly ventilated roofs.

  • Design allows direct ventilation to the roof space and can be used with all roof tiles
  • Can be used as a terminal for soil and ventilation pipes and mechanical extraction systems when used with an adaptor (100mm and 125mm) and flexipipe
  • Provides ventilation without the need for a breathable membrane
  • Available Colours:

    Klober Universal Tile Vent Antique Red

    Compatible with:

    More Information

    The Universal Tile Vent is the perfect solution for ventilating roof voids. It helps to reduce the build-up of mould growth and structural damage in the roof space, caused by damp, poorly ventilated roofs. It also provides an exit location for soil and ventilation pipes as well as mechanical extraction systems. The Universal Tile Vent suits most concrete interlocking roof tiles or plain roof tiles with a minimum pitch of 17.5° and providing 15,000mm2 of ventilation coverage. The low profile design is available in a wide range of colours to blend with the roof tiles.

    Specifications

    Technical Data
    Colour
    Antique Red
    Material
    UPVC
    Minimum Pitch
    17.5
    Ventilation Area
    15000 mm2
    Vent tile spacing 5 000 mm2
    3 m
    Vent tile spacing 10 000 mm2
    1.5 m
    Vent tile spacing 25 000 mm2
    0.6 m
    Dimensions and Weights
    Width
    424mm
    Length
    454mm
    Depth
    91mm
    Packaging
    Number of Pieces per Carton/Pack
    10
    Number of Pieces per Pallet
    80
    Weight per Piece
    1.89 kg
    Technical Data
    Colour
    Slate Grey
    Material
    UPVC
    Minimum Pitch
    17.5
    Ventilation Area
    15000 mm2
    Vent tile spacing 5 000 mm2
    3 m
    Vent tile spacing 10 000 mm2
    1.5 m
    Vent tile spacing 25 000 mm2
    0.6 m
    Dimensions and Weights
    Width
    424mm
    Length
    454mm
    Depth
    91mm
    Packaging
    Number of Pieces per Carton/Pack
    10
    Number of Pieces per Pallet
    80
    Weight per Piece
    1.89 kg
    Technical Data
    Colour
    Terracotta
    Material
    UPVC
    Minimum Pitch
    17.5
    Ventilation Area
    15000 mm2
    Vent tile spacing 5 000 mm2
    3 m
    Vent tile spacing 10 000 mm2
    1.5 m
    Vent tile spacing 25 000 mm2
    0.6 m
    Dimensions and Weights
    Width
    424mm
    Length
    454mm
    Depth
    91mm
    Packaging
    Number of Pieces per Carton/Pack
    10
    Number of Pieces per Pallet
    80
    Weight per Piece
    1.89 kg
    Technical Data
    Colour
    Brown
    Material
    UPVC
    Minimum Pitch
    17.5
    Ventilation Area
    15000 mm2
    Vent tile spacing 5 000 mm2
    3 m
    Vent tile spacing 10 000 mm2
    1.5 m
    Vent tile spacing 25 000 mm2
    0.6 m
    Dimensions and Weights
    Width
    424mm
    Length
    454mm
    Depth
    91mm
    Packaging
    Number of Pieces per Carton/Pack
    10
    Number of Pieces per Pallet
    80
    Weight per Piece
    1.89 kg
    Technical Data
    Colour
    Black
    Material
    UPVC
    Minimum Pitch
    17.5
    Ventilation Area
    15000 mm2
    Vent tile spacing 5 000 mm2
    3 m
    Vent tile spacing 10 000 mm2
    1.5 m
    Vent tile spacing 25 000 mm2
    0.6 m
    Dimensions and Weights
    Width
    424mm
    Length
    454mm
    Depth
    91mm
    Packaging
    Number of Pieces per Carton/Pack
    10
    Number of Pieces per Pallet
    80
    Weight per Piece
    1.89 kg

    Installation

    • Position vent tile in desired location and mark area of membrane to be cut
    • Carefully cut the marked area to the bottom and sides, fold back the flap and secure to tiling batten above
    • If using an adaptor for connection it is advised to connect prior to installation
    • Position vent tile, nail fix to upper batten and secure the lower butyl strip on the skirt to a clean dry and dust free tile below
    • Continue tiling as normal then apply cap ensuring this is firmly clipped into place

    Area of application

    • For roof pitches 17.5° and over
    • For most traditional concrete interlocking and plain tiles
    • High and low level ventilation

    Standards and Certifications

    10 Year Guarantee
    10 Year Guarantee
    10 Year Guarantee
    10 Year Guarantee
    10 Year Guarantee
    BS 5250 for Ventilation

    Your Free Guide to Roofing Ventilation

    Download our free Guide to Roofing Ventilation today for information on the importance of correct roof ventilation, the applicable British Standards, and how Klober's product range can support healthy roof space ventilation to prevent the build up of moisture and condensation.

    Download

    Guide to Roofing Ventilation | Roofing Vent Tiles, Double Roman Vent Tiles and Slate Roof Vents

    Download our free Guide to Roofing Ventilation today for information on the importance of correct roof ventilation, the applicable British Standards, and how Klober's product range can support healthy roof space ventilation to prevent the build up of moisture and condensation.

    Download

    Brochure Download

    Download our latest Product Guide

    Find a stockist